Logos Biosystems

Cell counting

Cell counting is an important quality control procedure in research. To increase accuracy and convenience, Logos Biosystems has developed broad range of automated cell counters and slides for counting all types of cells and bacteria. In addition we also offer several cell counting reagents.  

LUNA-STEM™

Automated Fluorescence Cell Counter
 

LUNA-II YF™

Automated Yeast Cell Counter
 


Compare Logos Biosystems cell counters 

 LUNA-II™LUNA-FX7™LUNA-FL™LUNA-STEM™LUNA-II YF™QUANTOM Tx™
Main featuresMost affordable cell counterVersatile cell counter that serves a wide variety of applications.
An excellent choice for higher throughput and/or regulatory needs.
Versatile and affordable fluorescence cell counter with manual focusFluorescence cell counter specialized for SVF derived- cellsAffordable yeast cell counterImage-based bacterial cell counter
Cell typesStable cell linesCell lines
Primary cells
Whole blood
PBMCs
Splenocyte
Thymocyte
Yeast cells
Cell lines
Primary cells
Blood cells
PBMCs
Splenocyte
Thymocyte
Yeast cells
GFP expressing cells
Stem cells
SVF-derived cells
• Nucleated
• Non-nucleated
Yeast cellsBacterial cells
Detection methodBrightfieldDual fluorescence
Brightfield
Dual fluorescence
Brightfield
Dual fluorescenceDual fluorescenceFluorescence
Compatible dyesTrypan blue
Erythrosin B
Trypan blue
Erythrosin B
Acridine orange
Propidium iodide
Fluorescein diacetate
Trypan blue
Erythrosin B
Acridine orange
Propidium iodide
Fluorescein diacetate
Acridine orange
Propidium iodide
Acridine orange
Propidium iodide
Fluorescein diacetate
QUANTUM Total Cell Staining Kit
QUANTUM Viable Cell Staining Kit
Recommended slide optionsLUNA™ Cell Counting Slide
LUNA™ Reusable Slide
PhotonSlide
LUNA™ 1-Channel Slide
LUNA™ 3-Channel Slide
LUNA™ 8-Channel Slide
PhotonSlide™
LUNA™ Reusable Slide
PhotonSlide™
LUNA™ Reusable Slide
PhotonSlide™
LUNA™ Reusable Slide
QUANTOM™ M50
Cell Counting Slide
Focusing optionsAutofocus
Manual focus
Autofocus
Manual focus
Manual focusManual focusAutofocus
Manual focus
Autofocus
Manual focus
Counting speed< 10 s (manual focus)
< 15 s (autofocus)
< 10 s (brightfield, without autofocus, 12 images)
< 20 s (brightfield, with autofocus, 12 images)
< 30 s (fluorescence, without autofocus, 12 images)
< 40 s (fluorescence, with autofocus, autofocus, 12 images)
< 10 s (brightfield)
< 30 s (fluorescence)
< 30 s< 10 s (manual focus)
< 15 s (autofocus)
< 30 s (autofocus, 10 images)
Adjustable protocol parametersCell size
Declustering
Dilution factor
Live cell sensitivity
Noise reduction
Roundness
Search size / Cell size
Cell detection sensitivity
Live cell sensitivity
Noise reduction
Fluorescence exposure
Fluorescence threshold
Dilution factor
Cell size
Dilution factor
Fluorescence threshold
Live cell sensitivity
Noise reduction
Roundness
Cell size
Dilution factor
Fluorescence threshold
Noise reduction
Roundness
Fluorescent object size
Dilution factor
Fluorescence exposure
Light intensity
Fluorescent object size
Dilution factor
Roundness
Declustering
Multi-field imaging
Additional featuresCell size gating
Cluster map
Dilution calculator
Review previous count results
Auto exposure
Cell size gating
Cluster map
Dilution calculator
Review previous count results
Bioprocess
Quality control
Reanalysis
Auto exposure
GFP expression analysis
Cell size gating
Cluster map
Dilution calculator
Review previous count results
Auto exposure
Cell size gating
Cluster map
Dilution calculator
Review previous count results
Fluorescent object size gating
Dilution calculator
Review previous  count results
Fluorescent object size
gating
Dilution calculator
Review previous count
results
Reanalysis
IQOQ protocolYesYesYesYes-Yes
21 CFR Part 11 ready-Yes (With CountWire™ software)----
Saving optionsCell count and viability data (CSV)
Raw image (TIF)
Analyzed image (annotated TIF)
Full report (PDF)
Cell count and viability data (CSV)
Raw image (TIF)
Analyzed image (annotated TIF)
Full report (PDF)
Bioprocess (Onboard, CSV, PNG graph images)
Quality Control (Onboard, CSV, PNG graph images)
Cell count and viability data (CSV)
Raw image (TIF)
Analyzed image (annotated TIF)
Full report (PDF)
Cell count and viability data (CSV)
Raw image (TIF)
Analyzed image (annotated TIF)
Full report (PDF)
Cell count and viability data (CSV)
Raw image (TIF)
Analyzed image (annotated TIF)
Full report (PDF)
Cell count data (CSV)
Raw image (TIF)
Analyzed image (annotated TIF)
Full report (PDF)
Data transferUSB memory stickUSB memory stick, WiFi, EthernetUSB memory stickUSB memory stickUSB memory stickUSB memory stick, WiFi
Technical specifications5” TFT LCD screen
800 X 480 pixels
Built-in computer
Built-in printer (optional)
7” TFT LCD screen
1024 X 600 pixels
Built-in computer
External printer (optional)
7” TFT LCD screen
800 X 480 pixels
Built-in computer
External printer (optional)
7” TFT LCD screen
800 X 480 pixels
Built-in computer
External printer (optional)
5” TFT LCD screen
800 X 480 pixels
Built-in computer
Built-in printer (optional)
10” TFT LCD screen
1280 x 800 pixels
Built-in computer
External printer (optional)
Onboard storage-250GB / 1TB---128GB
Weight1.6 kg 4.5 kg1.8 kg1.8 kg1.8 kg10.8 kg
Dimensions16 x 18 x 28 cm24.5 x 28 x 24 cm22 x 21 x 9 cm22 x 21 x 9 cm16 x 18 x 28 cm43.3 × 31.0 × 22.5 cm

Reach out for more information!

Marte Sødal

Product specialist

marte@bionordika.no

Marte Sødal

 

Contact us 

By submitting this form, you agree to our Privacy Policy and consent to receive our digital newsletters and updates. We respect your privacy and will not share your information. You can unsubscribe at any time. Read our Privacy Policy for more details.